0
RANGE

Glass Epoxy Laminated Sheet - G10 (130 °C), HGW 2372, EPGC 201

Glass Epoxy Laminated Sheet - G10 (130 °C), HGW 2372, EPGC 201
18.0 × 1240 × 2800 mm
In Stock
1 657,40 EUR
Glass-epoxy rigid boards EPGC 201

NORMATIVE REFERENCES
Glass-epoxy laminated sheets EPGC 201 meet requirements of:
EPGC 201 acc. to IEC 60893
HGW2372 acc. to DIN7735
G-10 acc. to ANSI/NEMA IM 60000

COMPOSITION
Glass-epoxy laminated sheets EPGC 201 consist of glass fabric with epoxy resin binder.

CHARACTERISTIC AND APPLICATIONS
Glass-epoxy laminated sheets EPGC 201 are characterized by good mechanical and electrical properties. They are intended for mechanical, electrical and electronic applications, where long-term thermal endurance in temperature about 130°C is critical.

TECHNICAL DATA
Property Test method Unit Average results
Flexural strength ISO 178 MPa 525
Impact strength (Charpy) ISO 179/3C kJ/m2 81
Modulus of elasticity in flexure ISO 178 GPa 22,9
Compressive strength ISO 604 MPa 626
Tensile strength ISO 527 MPa 410
Shearing strength IEC-893-2 MPa 47
Electric strength at 90 °C in oil perpendicular to laminations (sample thickness 3,0 mm) IEC 243-1 kV/mm 16
Breakdown voltage at 90 °C in oil parallel to laminations IEC 243-1 kV 60
Insulation resistance after immersion in water IEC 167 2,4×106
Comparative tracking index IEC 112 - 200
Permittivity IEC 250 - 5,0
Dissipation factor IEC 250 - 0,009
Water absorption (sample thickness 3,0 mm) IEC 62 mg 6,0
Density ISO 1183 g/cm3 1,89
Thermal conductivity ISO 8302 W/mK 0,44
Coefficient of thermal expansion at X direction MD Dilatometry 10-5/K 1,4
Coefficient of thermal expansion at Y direction CD Dilatometry 10-5/K 1,2
Coefficient of thermal expansion at Z direction (perpendicular to laminations) Dilatometry 10-5/K 6,1